Pneumafil Duct
We have been successfully doing conversion of Pneumafil Suction Arrangement in LR G 5/1, LR 6, 6S and Chinese Ring Spinning machines and Compact Spinning frames by REPLACING the Individual Plastic Suction Tubes with that of common T-Type suction pipes by keeping the exisiting central suction duct as it is.The following comparative study will show the facts better.
We are also manufacturer of duct for all type of Ring frames.
Comparative Study Details |
Monometer Suction Pressure In cm Water column |
Before Conversion |
After Conversion |
Pressure Improvement |
Off End |
10 |
15 |
50% |
Middle |
6 |
10 |
80% |
Gear End |
4 |
8 |
100% |
|
Payback Period In Each R/Frame in an Year |
|
|
|
Motor Load In Amps |
7.5A |
5.5A |
Savings 2.0A |
Energy Saving Per Hour= |
2.0 x 1.732 x 420v x 0.95 / 1000 = 1.38 unit |
|
|
Energy Saving Per Day= |
1.38 x 24 = 33.12 units |
|
|
Energy Saving Per Year= |
33.12 x 365 = 12088.8 units |
|
|
Energy Cost Saving Per Year@Rs.5.50 per Unit= |
12088.8 x 5.50/- = Rs. 66,484/- |
|
|
|